• Sources: primary
  • Summary: ClickHouse Cloud found nodes that stayed Ready while pods failed writes, such as an EC2 node with a failed NVMe member of a RAID array, because the upstream Node Problem Detector rule for EXT4 errors only emitted an event that expires after an hour. It now runs one NPD rule catalog on AWS, GCP and Azure with permanent conditions and plugin checks, such as NVMe timeouts on two devices within a minute, and a new open-source controller, node-problem-mitigator, that evaluates, drains or terminates nodes per condition behind a kill switch, exclusions and a global cooldown. A Node Debug Collector captures a diagnostic bundle before the node is removed.
  • Why it matters: Kubernetes Ready status misses disk, kernel and runtime faults, and this gives a tested rollout pattern and an open-source controller for acting on Node Problem Detector conditions.
  • Background: The kubelet reports only its own view of a node through conditions such as Ready, MemoryPressure and DiskPressure. Node Problem Detector is a DaemonSet that tails kernel and system logs or runs probe scripts and publishes the results as node conditions or short-lived events. Nothing in core Kubernetes acts on those custom conditions, so a separate controller has to drain or replace the node.